Cell Signaling · Unit 8: Evolution, disease and tools

Hacking the Cell: Reporters, Actuators and Genetic Tools

How do you watch a signal inside a living cell, and how do you start one in a cell of your choosing?

The main idea, the figures and what the films show. Under each heading, "Read this part" opens it.

Both films in order, 7 minutes. Each one ends with what to take from it.

The whole lesson: about 19 minutes of reading and 7 of film.

This idea at other levels

This lesson teaches knockout mice in Cell Signaling, a graduate course. Simpler: read a short college version here.

The college version · about 1 minute to read

A reporter is a genetically encoded biosensor: a fluorescent protein fused to a detector domain so that its brightness, position or color changes with a signal. GFP suits the job because its chromophore forms from three of its own residues and needs only oxygen, so the gene is enough in many kinds of cell. GCaMP joins a circularly permuted GFP to calmodulin and a calmodulin-binding peptide and brightens when calcium binds. Kinase reporters put a substrate peptide and a phospho-binding domain between two fluorescent proteins and report by FRET. An actuator starts a signal: channelrhodopsin-2 is a seven-helix, retinal-binding protein that is itself a cation channel opened by blue light, and halorhodopsin pumps chloride inward to suppress firing, though prolonged use loads the cell with chloride. Chemogenetic receptors do a similar job with a drug. Targeting to a cell type comes from genetics: transgenes with chosen promoters, knock-ins made by homologous recombination in embryonic stem cells, and Cre recombinase, which removes DNA between loxP sites only in cells that make Cre. Localization microscopy such as PALM then places single switched-on molecules to within tens of nanometers, below the diffraction limit of about 200 nanometers.

See every levelHide the levels

This lesson also teaches two more ideas; their ladders are below.

Transgenic and knockout mice (Cre and lox)

Scientists add, remove or change a gene in a mouse, and with Cre and lox they do it only in chosen cells.

Taught at one level so far: graduate level.

  1. Graduate

    Hacking the Cell: Reporters, Actuators and Genetic Tools · this lesson

    Transgenes, knock-ins and Cre at loxP put a tool into one cell type.

    Cell Signaling · about 19 min · film 3:24 · 3 practice questions

    Tools for Following Cells and Genes

    Cre cuts a floxed gene only where it runs; reporter light is not deletion.

    Developmental Neuroscience · about 26 min · film 3:11 · 3 practice questions

Next door to knockout mice

Everything on knockout mice, films included

Fluorescent reporters

A glowing protein joined to a detector lets you watch where and when a signal happens inside a living cell.

Taught at one level so far: graduate level.

  1. Graduate

    Hacking the Cell: Reporters, Actuators and Genetic Tools · this lesson

    GFP joined to a detector: GCaMP brightens with calcium, FRET reporters watch kinases.

    Cell Signaling · about 19 min · film 3:24 · 3 practice questions

Next door to fluorescent reporters

Everything on fluorescent reporters, films included

Optogenetics

A light-gated channel from a microbe is placed in chosen cells, so a flash of light switches those cells on or off.

Taught at two levels: upper-level college and graduate level.

  1. Graduate

    Hacking the Cell: Reporters, Actuators and Genetic Tools · this lesson

    Channelrhodopsin-2: blue flashes make hippocampal neurons fire, millisecond by millisecond.

    Cell Signaling · about 19 min · 3 practice questions

  2. College, upper level

    Designing a Causal Circuit Experiment

    Construct-by-light two-by-two: light alone changed firing in mice with no opsin.

    Neuroscience · about 23 min · film 3:23 · 3 practice questions

Next door to optogenetics

Everything on optogenetics, films included

Short versions inside this lesson

The plainest version · about 1 minute to read

Some jellyfish carry a tiny part that glows green. Scientists copied the instructions for that part into the cells of mice, so that chosen cells light up, and light up more when they are busy. They also borrowed a part from pond algae that works like a light switch: shine blue light on a cell that has it, and the cell turns on. So now they can watch a cell work, and they can also tell it when to work.

Find an idea: every idea, searchable

Which lessons teach an idea, and the notes on each level, were written by AI models from the lessons and checked by a second model. A person has not yet read every one. How we use AI

About this lesson goals, parts

What you'll learn

  • Tell a reporter from an actuator: a reporter lets you watch a signal in a living cell, and an actuator lets you start one on command.
  • Explain how a fluorescent protein from a jellyfish became a tool, and how a reporter for calcium or for a kinase is built from it and from parts met in earlier lessons.
  • Explain how a light-gated channel from a microbe switches on a chosen neuron, and describe one other way to switch a chosen cell on.
  • Describe how transgenes, knock-outs, knock-ins and the Cre and lox system put a tool into one cell type, and say how microscopes got past the limit set by the wavelength of light.

Builds on:Calcium: The Messenger Kept at Arm's LengthSensing the World: Vision, Smell, Nitric Oxide and cGMPProtein Modules: SH2, SH3, PTB, PDZ and PHWhy these?

Rewritten on : new text and film. Notes and highlights stay, but the text around them may have moved.

The main idea. Reporters turn signals into light, and actuators control them on command; promoters and recombinases place each tool in chosen cells.

The films

▶ Watch Watch It or Push It: Reporters and Actuators · 3:24
Watch It or Push It: Reporters and Actuators · 3:24
Read the transcript of “Watch It or Push It: Reporters and Actuators”

Film transcript: Watch It or Push It: Reporters and Actuators

Every time a mouse turns left, one hidden neuron fires. How can you watch that living signal, and test whether it causes the turn? Signals inside cells are tiny and fast. Engineered proteins let you answer both questions with light.

Two kinds of protein do the work. A reporter turns a cell's signal into light so you can watch it live. An actuator works the other way. It turns a flash of light or a drug into a signal on command. Reporters start with green fluorescent protein from a jellyfish. How does fluorescence work? A molecule absorbs a blue photon and lifts an electron. A little energy leaves as heat before a green photon comes out. So light leaves at a longer wavelength than it entered. Green fluorescent protein folds into a tight barrel with its glowing center shielded inside. Under blue light, that sealed barrel glows steadily. To make brightness track calcium, engineers cut a narrow slit beside that glowing center. Water slips through the slit and dims the glow.

Next, engineers attach a calcium detector called calmodulin to one edge, and a partner peptide to the other. That hybrid sensor is GCaMP. When calcium enters, calmodulin grabs it and wraps around the peptide. Together they plug the slit, shut water out, and brighten the barrel. Every time the mouse turns left, this GCaMP neuron flashes bright green.

Pause and think. Does that flash prove firing this neuron causes the turn, or could another circuit drive both? Watching alone cannot prove causation, because another brain circuit could drive both the turn and the calcium flash at once. So to test causation, you cannot only watch. You must push this neuron yourself and see what the mouse does. That takes an actuator. Meet channelrhodopsin-2, borrowed from a green alga. Like rhodopsin in your eye, it holds light-sensing retinal inside seven membrane helices. Your eye's protein then passes the message to a G protein, a go-between. Channelrhodopsin-2 skips that go-between: it is itself an ion pore.

Flash blue light onto the membrane. Retinal shifts shape, and the pore opens within milliseconds. Cations rush in, and their positive charge makes the inside less negative. The voltage climbs past the firing threshold, the neuron fires, and the mouse turns left. Both tools are engineered proteins that living cells can build from a gene. Put them together and you hold the first rule. Reporters turn signals into light, and actuators control them on command.

From the film: four take-homes
  • Reporters turn signals into light, and actuators control them on command.
  • In GCaMP, calcium makes calmodulin wrap its peptide and plug a gap in the GFP barrel, shutting water out so the protein brightens.
  • Watching a reporter shows when a signal happens, not whether it causes an effect; testing causation takes an actuator.
  • Channelrhodopsin-2 is a light-gated cation channel, so blue light opens its pore directly without a G-protein relay.

Two engineered protein classes let you work on a signal in a living cell: a reporter watches where and when it happens, and an actuator pushes or stops it on command. The first film paired a calcium reporter with a light-gated channel; here we examine why GFP needs no jellyfish enzyme, expand the toolkit to lipids, pH, kinases and drugs, and then turn to genetic targeting and super-resolution microscopy.

The one idea. Reporters turn signals into light, and actuators control them on command; promoters and recombinases place each tool in chosen cells. Scope: Applies to genetically encoded optical and chemical tools, including simple fluorescent tags that mark location. Reporters can buffer or blur fast signals, actuators can shift extra ions or need drug controls, Cre cuts are permanent across descendants and can leak, and resolving molecules closer than about 200 nanometers requires super-resolution methods such as PALM.

GFP and the reporter toolkit

A reporter is an engineered protein whose light changes with a signal; an actuator changes a cell’s activity on command, starting or stopping a signal (like a voltmeter versus a switch, or an electrode). Using light and a gene to control cells is called optogenetics, a word often stretched to cover reporters used alongside it.

In fluorescence, absorbing a photon lifts an electron; some energy leaves as heat before a longer-wavelength photon is emitted (blue in, green out). In 1992, moving only the protein-coding stretch of jellyfish green fluorescent protein (GFP) into E. coli made the bacteria glow green—ruling out the assumption that a jellyfish enzyme had to finish it.

Structure explains why: GFP folds into a barrel with a central helix whose three neighboring amino acids react, lose water, and are oxidized by oxygen from the air into a rigid ring absorbing violet and blue light and emitting green. Because the recipe is the sequence itself, many cells with the gene and oxygen build their own lamp—though the first version folded poorly in warm cells—and fusing another gene to GFP tags that protein directly.

Predict. You express the GFP gene in human cells kept at 37 °C in an oxygen-free chamber. Will they glow green?

Check your prediction

No. No jellyfish enzyme is needed, but forming GFP’s light-emitting ring requires molecular oxygen—and the original jellyfish protein also folded poorly in warm mammalian cells before improved variants were engineered.

Four ways to wire a reporter

The simplest fusion marks location: GFP fused to gephyrin, a scaffold under inhibitory synapses, lights up a neuron’s dendrites in rows of bright dots.

To track an active signal, fuse GFP to a signaling detector so the signal alters location, brightness, or color ratio:

  • Location — lipid reporter. A PH domain binding phosphatidylinositol 3,4,5-trisphosphate (PIP3) (see the lesson on lipid anchors and addresses), fused to GFP, shifts from cytosol to membrane when PI 3-kinase makes PIP3.
  • Brightness — pH reporter. An acid-dimming GFP facing inside a synaptic vesicle (pH about 5.5) brightens on fusion when it meets extracellular fluid at pH 7.4 (a roughly 80-fold drop in proton concentration).
  • Brightness — calcium reporter (GCaMP). Expanding on the first film: engineers join GFP’s original ends and cut new ends beside the chromophore so water dims the barrel. Calmodulin (from the calcium lesson) on one new end and its target peptide on the other wrap together when calcium rises, plugging the gap and shutting water out.
  • Color ratio — kinase reporter (FRET). Place a kinase substrate peptide and a phospho-binding domain (an SH2 domain for a tyrosine kinase) between cyan (donor) and yellow (acceptor) fluorescent proteins. Phosphorylation folds the chain so the pair sit within a few nanometers, letting cyan pass energy to yellow without a photon (Förster resonance energy transfer, FRET) and raising the yellow-to-cyan ratio; phosphatases reverse it.
In GCaMP, calcium makes calmodulin wrap its peptide and plug a gap in the GFP barrel, shutting water away from the light-emitting group so fluorescence brightens. AI-generated illustration

Predict. In a cell with a tyrosine-kinase FRET reporter, a drug blocks phosphatases while basal kinase activity continues. Does the yellow-to-cyan ratio rise or fall?

Check your prediction

It rises. The reporter tracks the kinase-phosphatase balance; blocking phosphatases lets phosphorylated, folded molecules accumulate, keeping donor and acceptor close and increasing transfer to yellow.

A reporter also perturbs what it reads: a calcium reporter buffers some of the calcium it measures, and its binding and shape changes take time, so in slower variants a fast spike train can blur into one slow rise.

Actuators: light or drugs in, signal out

In the lesson on the senses and cGMP, retinal rhodopsin uses seven helices and retinal to trigger a G protein. As the first film showed, green-algal channelrhodopsin-2 skips that relay—it is itself a cation channel opened within milliseconds by blue light. Already shown to work in mammalian cells, it was used in 2005 by Edward Boyden, Feng Zhang, Ernst Bamberg, Georg Nagel and Karl Deisseroth to make cultured hippocampal neurons fire action potentials in step with millisecond blue flashes; other laboratories reported similar results about the same time.

ActuatorMechanismLightEffect and key limit
Channelrhodopsin-2 (and relatives)Direct non-selective cation channelBlue (other variants use other colors)Cations enter, firing the neuron; some relatives pass anions instead.
HalorhodopsinsChloride pump (1 Cl⁻/photon)YellowDrives Cl⁻ in to suppress firing; needs bright light, and Cl⁻ loading makes the chloride gradient shallower, weakening inhibition. Light-gated Cl⁻ channels are now used more often for silencing.
OptoXRsChimeric GPCR (inner loops from another GPCR)GreenStarts that chosen receptor’s G-protein pathway instead of opening a pore.

A virus can deliver an opsin to one brain region—though the adeno-associated virus (AAV) vectors used most hold only a short promoter—with light supplied through an optical fiber.

For wireless control over minutes to hours without a fiber, chemogenetics substitutes a drug:

  • DREADDs (Designer Receptors Exclusively Activated by Designer Drugs): engineered G-protein-coupled receptors (GPCRs) that barely answer their natural ligand and answer a synthetic drug instead, so in the main only cells with the receptor react. A drug control is essential: clozapine-N-oxide (CNO), used most, converts into clozapine in the body, which acts on the animal’s own receptors.
  • Transient receptor potential vanilloid 1 (TRPV1) (from the lesson on ion channels): expressing TRPV1 in one neuron type of a TRPV1 knock-out mouse lets capsaicin open a cation channel in those neurons alone (Güler and colleagues, 2012).

Predict. To silence one neuron population for two hours in a freely moving mouse without an implanted fiber, which actuator fits best, and what control does CNO require?

Check your prediction

An inhibitory Gi-coupled DREADD fits best: opsins require a fiber, and halorhodopsin also loads chloride over long exposures. Give the same CNO dose to control mice lacking the DREADD to separate receptor effects from clozapine.

Every reporter, opsin, or DREADD above is a protein encoded by DNA, which raises the second half of the problem: how to put its gene into one chosen cell type in a living mouse.

Watch Putting the Tool in One Cell Type · 3:08
Read the transcript of “Putting the Tool in One Cell Type”

Film transcript: Putting the Tool in One Cell Type

In the first film, you met a glowing reporter and a light-gated actuator. In a brain with billions of cells, how do you put them into one chosen cell type? Almost every cell holds the same chromosomes, so control comes from where a gene is read. Start with a transgene, a piece of engineered DNA added to a fertilized egg. Every transgene pairs two parts. The promoter decides where and when a gene runs. The coding sequence decides which protein the cell builds. Pair a promoter active in every cell with the green fluorescent protein gene. Every cell reads it, and you get a glowing green mouse. That proves a transgene works, yet every neuron lights up at once.

You still cannot isolate one cell type. To target one cell type cleanly, split the job across two genes. Put your reporter behind a strong promoter, then block it with a stop signal that halts reading. Flank that stop block with two short tags called loxP, pointing the same way. With the stop intact, every cell stays dark. Now bring in a recombinase called Cre, an enzyme from a bacterial virus. A recombinase cuts and rejoins DNA, and Cre does it at loxP sites. Here is the twist. Cre turns a gene on by deleting DNA. It cuts out the stop block, clears the roadblock, and lets the cell build the tool. So which cells make Cre? Place the Cre gene behind a promoter active mainly in neuron type A. Type A makes Cre, snips out the stop, and lights up green.

Neighboring cells never make Cre, keep their stop blocks, and stay dark. Pause here for a key consequence. Cre removed that stop block from neuron A's chromosome for good. Suppose that cell later divides, and its daughter cells stop making Cre. Do those daughter cells still make the glowing reporter?

Yes, they do. Because the stop block is gone from the chromosome, every descendant inherits the unlocked gene. That permanent mark lets biologists trace cell lineages. Yet it carries a catch. Brief early Cre activity can unlock unintended cells too, so check every Cre line with a reporter. Need a second tool in neuron type B? Add Flp, a yeast enzyme that cuts only its own sites. Drive Cre in type A and Flp in type B, and each unlocks its own tool cleanly. Promoters and recombinases place each tool in chosen cells.

From the film

  • Promoters and recombinases place each tool in chosen cells.
  • In a transgene, the promoter decides where and when a gene is read, and the coding sequence decides what is made.
  • Cre turns a gene on by cutting out a stop block between two same-direction loxP sites, and the cut is permanent across descendants.
  • Because brief early Cre expression can cut DNA elsewhere, every Cre line must be checked with a reporter; adding Flp lets you address a second cell type.

Genetic addressing: putting a tool into one cell type

The second film showed why a ubiquitous promoter lights up every cell and how Cre removes a stop block; here are the genome-editing routes that build those mice and the logic for targeting two cell types.

Transgenes, gene targeting, and CRISPR

A transgene pairs a promoter (where and when a gene is read) with a coding sequence (what is made). Injected into a fertilized mouse egg, it sometimes integrates at a random chromosomal site and is inherited if it reaches the germ line. In 1982 Richard Palmiter and colleagues paired a metallothionein promoter with a growth hormone gene to produce giant mice; a ubiquitous promoter with GFP yields a green mouse.

To edit one chosen gene instead, work in embryonic stem cells (early-embryo cells able to form any tissue): flanking DNA swaps your edit into the target locus by homologous recombination. Destroying the gene is a knock-out; inserting something new (such as GFP or Cre) is a knock-in. Altered cells injected into an early embryo form a chimera whose germ-line offspring can inherit the edit (see Going deeper for selection and breeding). CRISPR now shortens this path: an RNA guide directs a DNA-cutting enzyme to a matching sequence in a fertilized egg, so many knock-outs and knock-ins no longer need stem cells or chimeras.

Conditional control with Cre, loxP, and Flp

Cre, from a bacterial virus, cuts and rejoins DNA at a 34-base-pair loxP site. Two same-direction loxP sites turn that single cutting reaction into an off or on switch:

  • Conditional knock-out (off): Flank an essential part of a gene with loxP sites. Cre removes it where Cre is made—so the gene is lost there and, in the main, nowhere else.
  • Conditional expression (on): Place a stop signal between two loxP sites ahead of the tool. Cre cuts the stop out permanently, so that cell and its descendants read the gene wherever the tool’s promoter is active (lineage tracing). Give Cre several fluorescent proteins to pick among at random, and neighboring cells take different colors.

Predict. You flank a coding exon of a kinase gene (not a stop block) with two same-direction loxP sites and express Cre in neuron type A. What happens in type A versus other cells?

Check your prediction

Cre excises the exon, knocking out the kinase in neuron type A and its descendants, while cells without Cre keep the exon and make the kinase normally.

Because the cut is permanent, every Cre line must be checked with a reporter: brief developmental or germ-line expression can cut DNA in unintended cells too.

For two tools in two neuron types of one mouse, pair Cre with yeast Flp, which cuts only its own sites:

Cell typeRecombinaseTool 1 (loxP-stop-loxP)Tool 2 (Flp-flanked stop)
Neuron type ACre onlyOn (stop cut)Off
Neuron type BFlp onlyOffOn (stop cut)
Other cellsNeitherOffOff

Past the limit of light

Even with a reporter in the right cell type, a lens cannot focus light to a point: one molecule spreads into a blur, and two molecules closer than about half a wavelength merge. Ernst Abbe wrote the limit in the 1870s:

smallest separable distance ≈ wavelength ÷ (2 × numerical aperture)

Numerical aperture measures how wide a light cone the lens collects—about 1.4 for a very good lens—giving a limit near 200 nanometers for green light, compared with about 40 nanometers across a synaptic vesicle.

Predict. Using 520 nm green light and a lens of numerical aperture 1.4, can a standard microscope separate two GFP-tagged proteins 50 nm apart on a synaptic vesicle?

Check your prediction

No: 520 ÷ (2 × 1.4) ≈ 186 nm, far wider than 50 nm, so their blurs merge.

One bypass came through Jennifer Lippincott-Schwartz’s NIH laboratory. In 2002 postdoc George Patterson built a photoactivatable GFP that starts dark and switches on with violet light. In 2005 physicist Eric Betzig proposed a microscope needing such a probe, and she gave Betzig and Harald Hess lab space. Their PALM method (published in 2006 alongside Xiaowei Zhuang’s STORM and Samuel Hess’s FPALM) turns on a sparse few molecules so blurs never overlap, locates each blur’s center, lets them bleach, and repeats thousands of times.

In the shot-noise approximation (neglecting background and pixel size), center uncertainty ≈ blur standard deviation ÷ √(photons collected): a 100 nm blur giving 100 photons is centered to about 100 ÷ 10 = 10 nm, yielding tens-of-nanometers detail. Other routes include STED (Stefan Hell, proposed 1994, shown 1999: a ring beam switches off fluorescence around the rim) and structured illumination (computing finer detail from striped lighting).

Design problem

Put both halves of the rule to work: pick a reporter and an actuator, then use promoters and recombinases to place them in chosen cells. First, how can you make a green animal? Second, design a mouse in which only one neuron type glows when calcium rises and can be switched on with light—naming the reporter, actuator, and targeting strategy.

One way to do it

The green animal is a transgene: a ubiquitous promoter joined to GFP, injected into fertilized eggs.

For the second mouse, breed three parts together:

  1. Address: Cre knocked into a gene read only by your neuron type.
  2. Reporter: A calcium reporter behind a lox-flanked stop.
  3. Actuator: A channelrhodopsin behind its own lox-flanked stop.

Only Cre-expressing cells remove the stops, so in the main only they and their descendants make both proteins; verify the line with a reporter first.

One trap: GCaMP is excited with blue light and channelrhodopsin-2 is opened by blue light, so looking also pushes. A red-shifted channelrhodopsin does not fix this, because retinal itself still absorbs blue light. Keep channelrhodopsin-2 and switch to a red-emitting calcium reporter such as RCaMP or jRGECO, excited with longer-wavelength (green-to-yellow) light that leaves the channel shut; then test that imaging light alone drives no current.

Going deeper

How GFP became a tool

From 1961 Osamu Shimomura and Frank Johnson extracted and purified aequorin, a jellyfish protein that gives off blue light when calcium binds it. Traces of a second protein, green and fluorescent, came along in the extract. In 1971 Morin and Hastings renamed it green fluorescent protein, GFP.

Until 1992 nobody knew whether the GFP gene alone would be enough. The common guess was that a jellyfish enzyme had to finish the protein. That year Douglas Prasher published the cloned gene, and in Martin Chalfie’s laboratory at Columbia the rotation student Ghia Euskirchen put its coding stretch into E. coli. The bacteria fluoresced green.

Once the protein folds, serine 65, tyrosine 66 and glycine 67 on the central helix react with one another, lose water, and are oxidized by oxygen from the air.

Who showed channelrhodopsins are channels

Georg Nagel, Peter Hegemann, Ernst Bamberg and colleagues had shown in 2002 and 2003 that channelrhodopsins from the green alga Chlamydomonas are light-gated channels, and that channelrhodopsin-2 passes cations and works in mammalian cells.

Selecting and breeding targeted mice

Drugs select the rare correct cells (random insertions keep an added herpes thymidine-kinase gene, and ganciclovir kills the cells that keep it). The chosen cells, from a strain with a brown ‘agouti’ coat, are injected into an early embryo of a black strain. The pup is a chimera, a patchwork of both, and if the stem cells formed its sperm or eggs, its agouti offspring can carry the change.

Injecting drug-selected agouti ES cells into a black-strain blastocyst produces a chimera whose agouti offspring can inherit the targeted allele, confirmed by genotyping. AI-generated illustration

Your notes

Select any text in the lesson to highlight it or add a note to it. Your highlights and notes are saved in this browser and collected in your notebook.

    Open your notebook →

    Try the Predict questions again

    Five Predict questions from this lesson, on their own. Answer each one first, then open its check.

    1. You express the GFP gene in human cells kept at 37 °C in an oxygen-free chamber. Will they glow green?

      From: GFP and the reporter toolkit

      Check your prediction

      No. No jellyfish enzyme is needed, but forming GFP’s light-emitting ring requires molecular oxygen—and the original jellyfish protein also folded poorly in warm mammalian cells before improved variants were engineered.

    2. In a cell with a tyrosine-kinase FRET reporter, a drug blocks phosphatases while basal kinase activity continues. Does the yellow-to-cyan ratio rise or fall?

      From: GFP and the reporter toolkit

      Check your prediction

      It rises. The reporter tracks the kinase-phosphatase balance; blocking phosphatases lets phosphorylated, folded molecules accumulate, keeping donor and acceptor close and increasing transfer to yellow.

    3. To silence one neuron population for two hours in a freely moving mouse without an implanted fiber, which actuator fits best, and what control does CNO require?

      From: Actuators: light or drugs in, signal out

      Check your prediction

      An inhibitory Gi-coupled DREADD fits best: opsins require a fiber, and halorhodopsin also loads chloride over long exposures. Give the same CNO dose to control mice lacking the DREADD to separate receptor effects from clozapine.

    4. You flank a coding exon of a kinase gene (not a stop block) with two same-direction loxP sites and express Cre in neuron type A. What happens in type A versus other cells?

      From: Genetic addressing: putting a tool into one cell type

      Check your prediction

      Cre excises the exon, knocking out the kinase in neuron type A and its descendants, while cells without Cre keep the exon and make the kinase normally.

    5. Using 520 nm green light and a lens of numerical aperture 1.4, can a standard microscope separate two GFP-tagged proteins 50 nm apart on a synaptic vesicle?

      From: Past the limit of light

      Check your prediction

      No: 520 ÷ (2 × 1.4) ≈ 186 nm, far wider than 50 nm, so their blurs merge.

    How we measure it

    Genetically encoded fluorescent reporters

    You join the gene for a fluorescent protein to the gene for a detector, such as calmodulin or a PH domain, and the cell makes the reporter itself. A fluorescence microscope then records the reporter's brightness, position or color over time in living cells, which tells you when and where the signal happened.

    Optogenetic stimulation

    You express a microbial opsin such as channelrhodopsin-2 in chosen cells and deliver light, in a dish from a lamp or laser and in an animal through an optical fiber. Recording the cell's voltage or the animal's behavior during the light tells you whether activity in those cells is enough to cause the effect.

    Gene targeting and Cre/lox conditional genetics

    You change one chosen gene in embryonic stem cells by homologous recombination, make chimeric mice from those cells, and breed the change into a line. With loxP sites placed around a piece of DNA, Cre recombinase removes that piece in the cells that make Cre and in their descendants, so a gene can be removed or switched on in largely one cell type.

    Single-molecule localization microscopy (PALM)

    You switch on a few photoactivatable fluorescent proteins at a time, find the center of each separate blur, and repeat for thousands of camera frames. The summed positions give an image with detail of tens of nanometers, well below the diffraction limit of about 200 nanometers.

    Method

    Open the method page →

    Practice questions on this lesson (3) → MCAT-style, original, each with an explanation

    That is the skim: you have the shape of it.

    That is both films: the lesson in pictures.

    The rest of the lesson is here when you want it.

    • Report an error

    Finish line

    Test yourself

    8 questions

    Practice and MCAT-style, with explained answers.

    That's the last lesson · Next course

    Developmental Neuroscience

    How a nervous system builds itself, one local decision at a time.

    Start the next course →

    Before you move on: review the questions you missed , or go back to all lessons in this course.

    ← Lesson 43 · How We Know: Detecting a Signal

    Rewritten on : new text and film. Notes and highlights stay, but the text around them may have moved.

    ↑ Top